Remote Control Commands
R&S
®
SMW200A
960User Manual 1175.6632.02 ─ 16
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:DIVider <Divider>
Sets the divider for the pulsed marker signal.
*)
 If R&S SMW-B9 is installed, the minimum marker duration depends on the sample/
symbol rate.
See "Marker Minimum Duration" on page 236.
Parameters:
<Divider> integer
Range:  2 (R&S SMW-B10) / 32* (R&S SMW-B9)  to  1024
*RST:  2
Example:  See Example "Managing waveform files" on page 920
Manual operation:  See "Marker Mode" on page 315
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:FREQuency?
Queries the pulse frequency of the pulsed marker signal. The pulse frequency is
derived by dividing the symbol rate by the divider.
Return values: 
<Frequency> float
Increment:  0.001
Example:  see Example "Managing waveform files" on page 920
Usage:  Query only
Manual operation:  See "Marker Mode" on page 315
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay <Delay>
Defines the delay between the signal on the marker outputs and the start of the sig-
nals.
Parameters:
<Delay> float
Range:  0  to  depends on other values
Increment:  0.001
*RST:  0
Default unit: Symbol
Example:  see Example "Managing waveform files" on page 920
Manual operation:  See "Marker x Delay" on page 260
SOURce Subsystem