Monitoring Signal Characteristics
R&S
®
SMW200A
601User Manual 1175.6632.02 ─ 16
"Baseband A". The level of the sum signal is still -31.76 dBm + -34.76 dBm = -
30 dBm.
9. Select "Fading A > Signal Routing (non-MIMO) > A to A&B, B to A&B" and select
"Fading A > Summation Ratio A/B = 3 dB" to boost the baseband A with 3 dB
more.
10. In the "Baseband Powers" dialog, configure three more measurements shown in
the following figure.