Monitoring Signal Characteristics
R&S
®
SMW200A
606User Manual 1175.6632.02 ─ 16
4. Select "IEEE 802.11 WLAN > General > State > On".
5. In the task bar, select "System Config > Setup > Baseband Powers", enable the
settings shown on the following figure, and select "Start" to trigger the measure-
ment.
The single measurement is started and lasts a given measurement time. Observe
the progress indication for information on the current progress status. The deliv-
ered measurement results of the submeasurements confirm the expected level
value of -35 dBm for the second frame block. All submeasurements retrieve equal
values because the selected repetition window is large and the measurement cap-
tures two gates (two frame active parts of the frame block 2).
Querying Information on the Baseband Power Levels