Network Login Commands
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
1066
10 Gigabit Ethernet ports such as those on the 10G4X I/O module and the uplink ports on the
Summit X450 family of switches do not support netlogin MAC-based VLANs.
If you attempt to configure netlogin MAC-based VLANs on 10 Gigabit Ethernet ports, the switch
displays an error message similar to the following:
ERROR: The following ports do not support the MAC-Based VLAN mode; 1, 2, 10
You can have a maximum of 1,024 MAC addresses per I/O module or per Summit X450 family
switch.
Displaying FDB Information. To view netlogin-related FDB entries, use the following command:
show fdb netlogin [all | mac-based-vlans]
The following is sample output from the show fdb mac-based-vlans command:
Mac Vlan Age Use Flags Port List
------------------------------------------------------------------------
00:04:96:10:51:80 VLONE(0021) 0086 0000 n m v 1:11
00:04:96:10:51:81 VLTWO(0051) 0100 0000 n m v 1:11
00:04:96:10:51:91 VLTWO(0051) 0100 0000 n m v 1:11
00:04:96:10:51:11 VLTWO(0051) 0100 0000 n m 8:1
00:04:96:10:51:31 VLTEN(0051) 0100 0000 d m 8:10
Flags : d - Dynamic, s - Static, p - Permanent, n - NetLogin, m - MAC, i - IP,
x - IPX, l - lockdown MAC, M - Mirror, B - Egress Blackhole,
b - Ingress Blackhole, v - NetLogin MAC-Based VLAN.
The flags associated with netlogin include:
v—Indicates the FDB entry was added because the port is part of a MAC-Based virtual port/VLAN
combination.
n—Indicates the FDB entry was added by network login.
Displaying Port and VLAN Information. To view information about the VLANs that are temporarily added
in MAC-based mode for netlogin, use the following command
show ports <port_list> information detail
The following is sample output from this command:
Port: 1
Virtual-router: VR-Default
Type: UTP
Random Early drop: Disabled
Admin state: Enabled with auto-speed sensing auto-duplex
Link State: Active, 100Mbps, full-duplex
Link Counter: Up 1 time(s)
VLAN cfg:
Name: Default, Internal Tag = 1(MAC-Based), MAC-limit = No-limit
...<truncated output>
Egress 802.1p Replacement: Disabled
NetLogin: Enabled
NetLogin authentication mode: Mac based
NetLogin port mode: MAC based VLANs
Smart redundancy: Enabled

Table of Contents