Power Over Ethernet Commands
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
536
show inline-power configuration ports
show inline-power configuration ports <port_list>
Description
Displays inline power configuration information for the specified ports.
Syntax Description
Default
N/A.
Usage Guidelines
The output displays the following inline power configuration information for the specified ports:
● Config—Indicates whether the port is enabled to provide inline power:
■ Enabled: The port can provide inline power.
■ Disabled: The port cannot provide inline power.
● Operator Limit—Displays the configured limit, in milliwatts, for inline power on the port.
● Label—Displays a text string, if any, associated with the port.
The following also displays for this command on modular PoE devices:
● Priority—Displays inline power priority of the port, which is used when the disconnect precedence
is set to lowest priority:
■ Low
■ High
■ Critical
Example
The following command displays inline power configuration information for ports 1 to 10 in slot 3 on a
modular switch:
show inline-power configuration port 3:1-10
Following is sample output from this command:
Port Config Operator Limit Priority Label
3:1 Enabled 15000 mW Low
3:2 Enabled 15000 mW Low
3:3 Enabled 15000 mW Low
3:4 Enabled 15000 mW Low
3:5 Enabled 15000 mW Low
port_list Specifies one or more ports.