EasyManua.ls Logo

Extreme Networks ExtremeWare XOS - Show Cfm Detail

Extreme Networks ExtremeWare XOS
2024 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commands for Connectivity Fault Management
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
448
show cfm detail
show cfm {<domain_name> {<association_name> {ports <port_list>} {[end-point
[inward-facing | outward-facing]]}}}} detail
Description
Displays the MEP CCM database.
Syntax Description
Default
N/A.
Usage Guidelines
If you don’t specify any parameters or variables, the system displays information on all CCM databases
on the switch.
This command displays the following items of the CCM database:
The name of the domain and association
Port number
MP and type
MAC address of remote end points
MEP IDs
Lifetime for CCM messages from each remote end point
Actual age of CCM messages
NOTE
The TTL for the CCM messages from the MP you are working on is 3.5 times the transmission interval.
domain_name Enter the name of the domain for which you want to display the MEP CCM
databases.
association_name Enter the name of the association for which you want to display the MEP CCM
databases.
port_list Enter the ports in the domain/association for which you want to display the
CCM databases.
inward-facing Enter this to display the CCM database on the inward-facing MEP for the
specified MA.
outward-facing Enter this to display the CCM database on the outward-facing MEP for the
specified MA.

Table of Contents

Related product manuals