configure vman add ports
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
747
configure vman add ports
configure vman <vman-name> add ports [ all | <port_list> ] {untagged |
tagged | nobroadcast }
Description
Adds one or more ports in a vMAN.
Syntax Description
Default
N/A.
Usage Guidelines
If you do not specify a parameter, the default value is untagged.
The vMAN tunnel begins at the ingress, or customer access, port and terminates at the egress, or trunk,
port. Traffic flows from the egress trunk port onto the network thereafter without the vMAN tag.
Ensure that all the switch-to-switch ports in the vMAN tunnel are configured as tagged ports. Configure
the vMAN ingress, or customer access, port as an untagged port (although this port does accept tagged
packets). You must configure the vMAN tunnel egress, or trunk, port as an untagged port so that the
vMAN header is stripped from the frame.
NOTE
You must configure the vMAN tunnel egress, or trunk, port as untagged so that the vMAN header is stripped from
the frame.
The vMAN must already exists before you can add (or delete) ports: use the create vman command to
create the VLAN. vMAN ports can belong to load-sharing groups.
The Extreme Networks default Ethernet type for vMAN is 088a8.
You cannot configure Connectivity Fault Management (CFM) on ports added to the vMAN.
vman-name Specifies a vMAN name.
all Specifies all ports.
port_list Specifies a list of ports or slots and ports.
untagged Specifies that the ports are untagged.
tagged Specifies that the ports are tagged.
nobroadcast Specifies that the ports do not forward broadcast, multicast, or unknown
unicast packets.
NOTE: This option is available only on the BlackDiamond 10808 and 12804
switch.