show inline-power info ports
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
539
Curr—Displays the measured current, in milliamperes, drawn by the PD.
Power—Displays the measured power, in watts, supplied to the PD.
Fault—Displays the fault value:
None
UV/OV fault
UV/OV spike
Over current
Overload
Undefined
Underload
HW fault
Discovery resistance fail
Operator limit violation
Disconnect
Discovery resistance, A2D failure
Classify, A2D failure
Sample, A2D failure
Device fault, A2D failure
Force on error
The detail command lists all inline power information for the selected ports. Detail output displays the
following information:
Configured Admin State—Displays the port’s configured state; Enabled or Disabled.
Inline Power State—Displays the port power state.
MIB Detect Status—Displays the port state as reported by SNMP; valid values are as follows:
disabled
searching
delivering
fault
test
otherFault
denyLowPriority
Label—Displays the port’s configured label.
Operator Limit—Displays the port’s configured operator limit value.
PD Class—Displays the class type of connected PD:
Max Allowed Power—Displays the amount of maximum allowed power for a device of this class.
Measured Power—Displays the measured power, in watts, supplied to the PD.
Line Voltage—Displays the measured voltage. A value from 0 to 2 is valid for ports in a searching
state.
Current—Displays the measured current, in milliamperes, drawn by the PD.
Fault Status—Displays the fault value.