configure sys-recovery-level slot
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
613
Table 17: Module recovery actions for the BlackDiamond 10808 and the BlackDiamond 12804
switches
Module Recovery Setting System Recovery Setting Hardware Action Taken
reset all
Single MSM Resets the MSM.
Dual MSM Resets the primary MSM and fails over to
the backup MSM.
I/O Module Resets the I/O module a maximum of
three times. After the third time, the I/O
module is permanently taken offline.
reset none
Single MSM Resets the MSM.
Dual MSM Fails over to the backup MSM.
I/O Module Resets the I/O module.
shutdown all
Single MSM The MSM is available for debugging
purposes only; however, you must clear the
shutdown state using the clear sys-
recovery-level command for the MSM
to become operational.
After you clear the shutdown state, you
must reboot the switch.
For more information see the clear
sys-recovery-level command.
Dual MSM The MSMs are available for debugging
purposes only; however, you must clear the
shutdown state using the clear sys-
recovery-level command for the MSM
to become operational.
After you clear the shutdown state, you
must reboot the switch.
For more information see the clear
sys-recovery-level command.
I/O Module Reboots the I/O module. When the module
comes up, the ports remain inactive
because you must clear the shutdown
state using the clear sys-recovery-
level command for the I/O module to
become operational.
After you clear the shutdown state, you
must reset each affected I/O module or
reboot the switch.
For more information see the clear
sys-recovery-level command.
shutdown none
Single MSM The MSM is available for debugging
purposes only.
Dual MSM The MSMs are available for debugging
purposes only.