configure vman ratelimit flood-traffic designated-port
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
899
Flags: (*) Active, (!) Disabled, (g) Load Sharing port
(b) Port blocked on the vlan, (a) Authenticated NetLogin port
(u) Unauthenticated NetLogin port, (m) Mac-Based port
Example
The following command designates port 5:5 as the port you are using the rate-limit profile to control the
flooding, multicast, and broadcast traffic in the egress rate-limit enabled vMAN metro:
configure vman metro ratelimit flood-traffic designated-port 5:5
History
This command was first available in ExtremeWare XOS 11.4.
Platform Availability
This command is available only on the BlackDiamond 12804 R-Series switch.