MOET
MOFL
M3FL
M1RWS M1AL M2RWS M2AL M3RWS M3AL
Figure 17-48. PLB Slave Error Syndrome Register 0 (PCICO_PLBBESRO)
31:29
MOET
Master 0 Error Type
000 No Error
001
Parity Error
010 Reserved
011
Reserved
100 Reserved
101
Non-configured Bank Error
110 Reserved
111
Reserved
28
MORWS
Master 0 Read/Write Status
o Error operation was a write
1 Error operation was a read
27
MOFL
Master 0 PCICO_PLBBESRO Field Lock
o PCICO_PLBB
ESRO
unlocked
1 PCICO_PLBB
ESRO
locked
26
MOAL
Master 0 PCICO_PLBBEAR Address Lock
o PCICO_PLBBEAR unlocked by Master 0
1 PCICO_PLBBEAR locked by Master 0
25:23
M1ET Master 1 Error Type See PCICO_PLBBESRO[MOET]
22 M1RWS Master 1 Read/Write Status
o Error operation was a write
1 Error operation was a read
21
M1FL Master 1 PCICO_PLBBESRO Field Lock
o PCICO_PLBB
ESRO
unlocked
1 PCICO_PLBB
ESRO
locked
20
M1AL Master 1 PCICO_PLBBEAR Address Lock
o PCICO_PLBBEAR unlocked by Master 1
1
PCICO_PLBBEAR locked by Master 1
19:17 M2ET
Master 2 Error Type See
PCICO_PLBBESRO[MOET]
16 M2RWS Master 2 Read/Write Status
o Error operation was a write
1 Error operation was.a read
15
M2FL Master 2
PCICO_PLBBESRO Field Lock
o PCICO_PLBB
ESRO
unlocked
1 PCICO_PLBB
ESRO
locked
14 M2AL
Master 2 PCICO_PLBBEAR Address Lock
o PCICO_PLBBEAR unlocked by Master 2
1
PCICO_PLBBEAR locked by Master 2
17-46 PPC405GP User's Manual
Preliminary