Remote Control Commands
R&S
®
SMW200A
1122User Manual 1175.6632.02 ─ 16
Example:
SYST:ULOC ON
activates the user interface lock.
Manual operation: See "User Interface" on page 689
:SYSTem:DLOCk <DispLockStat>
Disables the manual operation via the display, including the front panel keyboard of the
instrument and the LOCAL key.
Parameters:
<DispLockStat> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 0)
Example:
SYST:DLOC ON
Activates the display lock. The instrument cannot be operated
via the display until it has been enabled with SYST:DLOC OFF.
Manual operation: See "User Interface" on page 689
:SYSTem:KLOCk <State>
Disables the front panel keyboard of the instrument including the LOCAL key.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 0)
Example:
SYST:KLOC ON
Locks the front panel and external controls.
To enable the controls, send SYST:KLOC OFF.
Manual operation: See "User Interface" on page 689
:SYSTem:PROTect<ch>[:STATe] <State>[, <Key>]
Activates and deactivates the specified protection level.
Suffix:
<ch>
.
Indicates the protection level.
See also "Protection" on page 686
Parameters:
<State> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 1)