Remote Control Commands
R&S
®
SMW200A
1129User Manual 1175.6632.02 ─ 16
:SYSTem:COMMunicate:SOCKet:RESource?
Queries the visa resource string for remote control via LAN interface, using TCP/IP
socket protocol.
Return values:
<Resource> string
Example: See Example "Finding out the used VISA ressource strings"
on page 1116.
Usage: Query only
:SYSTem:COMMunicate:USB:RESource?
Queries the visa resource string for remote control via the USB interface.
Return values:
<Resource> string
Example: See Example "Finding out the used VISA ressource strings"
on page 1116.
Usage: Query only
:SYSTem:HELP:EXPort
Saves the online help as zip archive in the user directory.
Example:
:SYSTem:HELP:EXPort
MMEM:CDIR?
// "/var/user"
MMEM:CAT?
// ..,"Log,DIR,4096","help.tgz,BIN,69836600"
// confirms that help zip archive is saved.
Usage: Event
Manual operation:: "Setup > Help > Export Help to User Path"
:SYSTem:IDENtification <Identification>
Selects the mode to determine the "IDN String" and the "OPT String" for the instru-
ment, selected with command :SYSTem:LANGuage.
Note: While working in a emulation mode, the R&S SMW specific command set is dis-
abled, that is, the SCPI command SYST:IDEN will be discarded.