Configuring the Internal Baseband Source
R&S
®
SMW200A
366User Manual 1175.6632.02 ─ 16
This parameter is identical to the one in the "General Setting" section.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier:COUNt on page 944
No
Indicates the carrier index ranging from 0 to (number of carriers -1).
Individual carriers can be set using the remote control commands by specifying the
index in the parameter CARR.
State
Switches On/Off a carrier.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:STATe on page 948
Carrier Freq [MHz]
Sets the carrier frequency.
Note: The carrier frequency can only be set in "Arbitrary Carrier frequency" mode. For
"Equidistant Carrier Spacing", the carrier spacing is determined automatically.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:FREQuency
on page 949
Gain
Sets the gain of a carrier.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:POWer on page 949
Phase
Sets the starting phase of a carrier.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:PHASe on page 949
Delay
Sets the starting delay of a carrier.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:DELay on page 950
File
Accesses the standard "File Select" function for selecting the input file. The input file
contains the I/Q signal that is modulated onto the carrier.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:FILE on page 950
Info
Indicates the sample rate, number of I/Q value pairs (number of samples), and the sig-
nal period of the selected file.
Generating Multi-Carrier Signals