Monitoring Signal Characteristics
R&S
®
SMW200A
598User Manual 1175.6632.02 ─ 16
To perform baseband power measurements using the continuous acquisition
The baseband power measurements using continuous acquisition analyze the com-
plete signal. Perform the following settings to generate a non-bursted WLAN 802.11n
signal in Baseband A, Baseband B, route, and sum both signals and measure the influ-
ence of the baseband signals on the generated signal in all these cases.
1. Press the PRESET key.
2. In the block diagram, select "Baseband A > IEEE 802.11" and perform the follow-
ing:
a) Select "IEEE 802.11 WLAN > Frame Blocks > Idle Time = 0"
b) Select "IEEE 802.11 WLAN > General > State > On"
3. In the task bar, select "System Config > Setup > Baseband Powers" and perform
the following:
a) "Source > Baseband A"
b) "Output > RF A"
c) "Acquisition > Continuous"
d) "Sweep Time = 1 s"
e) "Run Mode > Auto"
f) Select "Add"
g) Select "Start" to trigger the measurement.