EasyManua.ls Logo

Rohde & Schwarz SMW200A - Page 941

Rohde & Schwarz SMW200A
1312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMW200A
926User Manual 1175.6632.02 ─ 16
// ******************************************************************
SOURce:BB:ARBitrary:WSEGment:SEQuence:SELect "play_list"
SOURce:BB:ARBitrary:WSEGment:SEQuence:APPend ON,0,1,NEXT
// adds the segment number 0 as a new (first) segment in the sequencing list
// this segment is activ and will be repeated once followed by the next segment
SOURce:BB:ARBitrary:WSEGment:SEQuence:APPend ON,3,2,NEXT
SOURce:BB:ARBitrary:WSEGment:SEQuence:APPend ON,2,1,SEG0
SOURce:BB:ARBitrary:TRIGger:SMODe SEQuencer
SOURce:BB:ARBitrary:TRIGger:SEQuence AAUTo
SOURce:BB:ARBitrary:TRIGger:SOURce INTernal
SOURce:BB:ARBitrary:STAT ON
SOURce:BB:ARBitrary:TRIGger:EXEC
Refer to "To apply a manual segment switch to the output segments in the required
order" on page 346 for description of the steps necessary to achieve a similar task via
manual operation of the instrument.
Example: Adding extra marker signals
The following example lists the commands necessary to add two marker signals, a
sequence restart marker and a segment restart marker, to the multi-segment
sequence. The example lists only the relevant commands.
// ******************************************************************
// Select the multi segment file and the corresponding configuration list
// ******************************************************************
MMEM:CDIR "/var/lists/ARB/multi_segment"
SOURce:BB:ARBitrary:WSEGment:CONFigure:CATalog?
// config
SOURce:BB:ARBitrary:WSEGment:CONFigure:SELect "config"
SOURce:BB:ARBitrary:WSEGment:CLOad "/var/user/ARB/multi_segment/config.inf_mswv"
SOURce:BB:ARBitrary:WSEGment:CONFigure:OFILe?
// "/var/user/ARB/multi_segment/ms_0to3.wv"
// ******************************************************************
// Enable restart markers on marker trace 1 and 2
// ******************************************************************
SOURce:BB:ARBitrary:WSEGment:CONFigure:MARKer:MODE IGNore
SOURce:BB:ARBitrary:WSEGment:CONFigure:MARKer:FSEGment MRK1
SOURce:BB:ARBitrary:WSEGment:CONFigure:MARKer:ESEGment MRK2
SOURce:BB:ARBitrary:TRIGger:OUTPut1:MODE UNCHanged
SOURce:BB:ARBitrary:TRIGger:OUTPut2:MODE UNCHanged
Example: Generating a multi carrier signal
The following example lists the commands necessary to generate a multi carrier signal.
SOURce Subsystem

Table of Contents