configure sys-health-check all level
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
603
System Behavior for the BlackDiamond 8800 Series Switch. Depending on your switch configuration,
Table 14 shows how the BlackDiamond 8800 series switch behaves when ExtremeWare XOS 11.5 detects
a fault:
System Behavior for the Summit X450 Family of Switches. Depending on your switch configuration,
Table 14 shows how the Summit X450 family of switches behave when ExtremeWare XOS 11.5 detects a
fault:
Displaying the System Health Check Setting. To display the system health check setting, including polling
and how ExtremeWare XOS handles faults on the switch, use the following command:
show switch
The system health check setting, displayed as SysHealth check, shows the polling setting and how
ExtremeWare XOS handles faults. The polling setting appears as Enabled, and the fault handling setting
appears in parenthesis next to the polling setting. In the following truncated output from a
BlackDiamond 8810 switch, the system health check setting appears as
SysHealth check: Enabled
(Normal)
:
SysName: TechPubs Lab
SysName: BD-8810Rack3
SysLocation:
Table 14: System behavior for the BlackDiamond 8800 series switch
Fault Handling Configuration Module Recovery Configuration Behavior
configure sys-health-
check all level normal
configure sys-recovery-
level slot none
The switch sends messages to the
syslog.
Same as above. configure sys-recovery-
level slot reset
Same as above.
Same as above. configure sys-recovery-
level slot shutdown
Same as above.
configure sys-health-
check all level strict
configure sys-recovery-
level slot none
Same as above.
Same as above. configure sys-recovery-
level slot reset
ExtremeWare XOS reboots the
affected switch or module.
Same as above. configure sys-recovery-
level slot shutdown
ExtremeWare XOS shuts down the
affected switch or module.
Table 15: System behavior for the Summit X450 family of switches
Fault Handling Configuration Hardware Recovery Configuration Behavior
configure sys-health-
check all level normal
configure sys-recovery-
level switch none
The switch sends messages to the
syslog.
Same as above. configure sys-recovery-
level switch reset
Same as above.
Same as above. configure sys-recovery-
level switch shutdown
Same as above.
configure sys-health-
check all level strict
configure sys-recovery-
level switch none
Same as above.
Same as above. configure sys-recovery-
level switch reset
ExtremeWare XOS reboots the
affected switch.
Same as above. configure sys-recovery-
level switch shutdown
ExtremeWare XOS shuts down the
affected switch.