EasyManuals Logo

Grandstream Networks UCM630X Series User Manual

Grandstream Networks UCM630X Series
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #249 background imageLoading...
Page #249 background image
P a g e | 249
UCM630X Series User Manual
Version 1.0.11.10
Direct Callback
Allows external numbers the option to get directed to the extension that last called
them.
For Example, User 2002 has dialed external number 061234575 but they were not
reachable, once they have received missed call notification on their phone, they
would mostly call back the number, if the option “Direct Callback” is enabled then
they will be directly bridged to user 2002 regardless of the configured inbound
destination.
Enable Concurrent
Call Alert
If enabled, the "Trunk Concurrent Calls" system event will monitor the number of
concurrent calls in this trunk. When the number of concurrent calls in a certain
period exceeds the set threshold, an alarm message will be generated. Note:
Please turn on the alert for the "Trunk Concurrent Calls" event first.
Two-way Concurrent
Calls Threshold
Threshold of all incoming and outgoing concurrent calls through this trunk.
Outgoing Concurrent
Calls Threshold
Threshold of all outgoing concurrent calls passing through this trunk.
Incoming Concurrent
Calls Threshold
Threshold of all incoming concurrent calls passing through this trunk.
Advanced Settings
Codec Preference
Select audio and video codec for the VoIP trunk. The available codecs are: PCMU,
PCMA, GSM, AAL2-G.726-32, G.726, G.722, G.729, G.723, iLBC, ADPCM,
H.264, H.265, H.263, H.263p and VP8.
Send PPI Header
If enabled, the SIP INVITE message sent to the trunk will contain PPI (P-Preferred-
Identity) header. The default setting is “No”.
Note: “Send PPI Header” and “Send PAI Header” cannot be enabled at the same
time. Only one of the two headers can be contained in the SIP INVITE message.
PPI Mode
Default Include the trunk’s preferred CID (configured in Basic Settings) in the
PPI Header.
Original CID Include the original CID in the PPI Header.
DOD Number Include the trunk’s DOD number in the PPI Header. If no DOD
number has been set, the trunk’s preferred CID will be used.

Table of Contents

Other manuals for Grandstream Networks UCM630X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks UCM630X Series and is the answer not in the manual?

Grandstream Networks UCM630X Series Specifications

General IconGeneral
BrandGrandstream Networks
ModelUCM630X Series
CategoryConference System
LanguageEnglish

Related product manuals