EasyManua.ls Logo

Rohde & Schwarz SMW200A - Page 160

Rohde & Schwarz SMW200A
1312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signal Routing and System Configuration
R&S
®
SMW200A
145User Manual 1175.6632.02 ─ 16
The dialog provides the settings for routing of the signal streams to the available
output connectors, the analog RF and I/Q output, and the digital I/Q output connec-
tors.
Meaning of the background colors:
Yellow: Streams mapped to the RF, I/Q and the BBMM connectors can be
added, possibly also frequency and phase shifted. At the BBMM connectors,
streams can also be output multiplexed.
Gray: The stream mapping to the FADER connectors is fixed.
Only single streams can be mapped; frequency offset cannot be applied.
If R&S SMBV or R&S SGT instruments are connected to the FADER connec-
tors and they are remotely controlled by the R&S SMW, the selected frequency
offset is applied to the RF signal of these instruments.
The settings are displayed in form of a stream matrix, where:
The number of rows is equal to the number of the generated streams
("System Configuration > Fading/Baseband Configuration > Advanced Mode"
and selected Entities (Users, Cells)*Streams (Rx Antennas))
The column display only the available digital output interfaces ("System Config-
uration > External RF and I/Q > Direction > Out").
Settings:
f
offset
, MHz....................................................................................................................145
Phase, deg..................................................................................................................146
Map Stream X to Connector........................................................................................146
Combination Mode......................................................................................................146
f
offset
, MHz
Sets an absolute frequency offset; streams routed to the RF, I/Q and BBMM connec-
tors are shifted in the frequency domain.
Frequency offset is also applied to R&S SMBV and R&S SGT instruments connected
to the FADER outputs.
Tip: Use this parameter:
To shift the used frequency band in the RF frequency section without modifying the
RF settings
To separate streams in the frequency domain, if these streams are added and
routed to the same output connector.
Note: The parameters "Baseband Offset" and "Frequency Offset" have different
impact.
Both parameters shift the signal in the frequency domain, but only the f
offset
affects the
calculation of the "Doppler Shift".
If the fading simulator is used, do not apply a "Baseband Offset" but do use the "Fre-
quency Offset" instead.
See also:
"Fading Simulation" user manual, description of the parameter "Dedicated Fre-
quency".
"Combination Mode" on page 146.
Remote command:
:SCONfiguration:OUTPut:MAPPing:STReam<st>:FOFFset on page 841
System Configuration Settings

Table of Contents

Related product manuals