Signal Routing and System Configuration
R&S
®
SMW200A
174User Manual 1175.6632.02 ─ 16
Settings:
Sample Rate Source...................................................................................................174
Sample Rate Value..................................................................................................... 174
Sample Rate Source
Selects whether the sample rate is estimated based on the digital input signal or is a
manually entered value (see also Chapter 3.3.4, "Important Signal Parameters and
Interface's Characteristics", on page 133).
"User Defined"
The sample rate is as defined the entry field value.
Note: An I/Q data clock is not necessary but the external signal
source (typically a second Rohde & Schwarz Instrument) and the
receiving Rohde & Schwarz Instrument have to be synchronized, i.e
they have to use common external reference signal.
"Digital I/Q In"
(for CODER connectors)
Estimates the sample rate based on the applied I/Q data clock and
displays the resulting value in the value field. The I/Q data clock sig-
nal is fed via the digital I/Q input.
Note: Estimation works best if the sample rate is close to the user
defined value.
Remote command:
[:SOURce<hw>]:BBIN:SRATe:SOURce on page 867
Sample Rate Value
Sets the sample rate of the external digital baseband input signal. The max. sample
rate depends on the connected transmitting device.
Remote command:
[:SOURce<hw>]:BBIN:SRATe[:ACTual] on page 867