Remote Control Commands
R&S
®
SMW200A
867User Manual 1175.6632.02 ─ 16
[:SOURce<hw>]:BBIN:MODE <Mode>
Defines that a digital external signal is applied.
Parameters:
<Mode> DIGital
*RST: DIGital
Example: see Example "Programming Example" on page 865
[:SOURce<hw>]:BBIN:SRATe:SOURce <Source>
Selects whether the sample rate is estimated based on the digital input signal or is a
user-defined value.
Parameters:
<Source> USER | DIN
DIN
Enabled for [:SOURce<hw>]:BBIN:DIGital:SOURce
CODER1|CODER2
*RST: USER
Example: See Example "Programming Example" on page 865
Manual operation: See "Sample Rate Source" on page 174
[:SOURce<hw>]:BBIN:SRATe[:ACTual] <Actual>
Sets the sample rate of the external digital baseband signal.
Parameters:
<Actual> float
Range for [:SOURce<hw>]:BBIN:DIGital:SOURce
FADER1|FADER2: 100E6|200E6
Range: 400 to 200E6
Increment: 0.001
*RST: 100E6
Example: see Example "Programming Example" on page 865
Manual operation: See "Sample Rate Value" on page 174
[:SOURce<hw>]:BBIN:DIGital:ASETting:STATe <State>
Activates automatic adjustment of the baseband input signal.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Programming Example" on page 865