Signal Routing and System Configuration
R&S
®
SMW200A
184User Manual 1175.6632.02 ─ 16
"Overflow/No Overflow"
Indicates whether the I/Q output signal is clipped or not. An additional
indication is displayed in the block diagram close to the correspond-
ing connector.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:OFLow:STATe? on page 1060
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:OFLow:STATe? on page 1060
"Overflow Hold"
Indicates an overload since last reset for evaluating the measure-
ment.
To reset the state, perform one of the following:
Select "Reset".
Start a new signal generation.
Change the output level.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:OFLow:HOLD:STATe? on page 1060
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:OFLow:HOLD:STATe?
on page 1060
"Reset"
Resets the "Overload Hold" indication.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:OFLow:HOLD:RESet on page 1060
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:OFLow:HOLD:RESet on page 1060
Power-On State
Selects the state which the I/Q digital output connectors are to resume after the instru-
ment is switched on.
"I/Q Out Off"
On power-on, the output is deactivated.
"Previous Setting"
Resumes the state that was active before the last switch off.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:PON on page 1057
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:PON on page 1057
Group Delay Compensation
(enabled for the BBMM connectors and connected R&S EX-IQ-BOX)
If you evaluate digital signals, enable this parameter so that the instrument compen-
sates the group delay response of the internal digital filters.
Remote command:
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:GDELay:CSTate on page 1060