General Configuration Command Set
Configuring Enterasys and Cisco Discovery Protocols
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 3-81
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to designate port ge.0.5 as untrusted:
3.2.6.13 set port ciscodp cos-ext
Use this command to set the CoS priority value which the Cisco IP phone should use to overwrite
the 802.1p tag of traffic transmitted by the device connected to the IP phone when the switch port
is configured to a Cisco DP trust state of untrusted (refer to the set port ciscodp trust-ext
command, Section 3.2.6.13). If a CoS priority value is not set with this command, by default the
Cisco IP phone will overwrite the 802.1p tag value with 0.
set port ciscodp cos-ext port-string {classify-value | undefined}
untrusted Tell the Cisco IP phone to overwrite the 802.1p tag of traffic
transmitted by the device connected to it to 0, by default, or
to the value configured with the set port ciscodp cos-ext
command (Section 3.2.6.13).
undefined No trust state setting is communicated to the Cisco IP phone.
Matrix>set port ciscodp trust-ext ge.0.5 untrusted