Security Configuration Command Set
Configuring MAC Authentication
14-40 Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
14.3.3.9 set macauthentication portreauthenticate
Use this command to force an immediate reauthentication of the currently active sessions on one or
more MAC authentication ports.
set macauthentication portreauthenticate [port-string]
Syntax Description
Command Type
Switch command.
Command Mode
Read-Write.
Command Defaults
If port-string is not specified, all MAC authentication ports will be forced to
reauthenticate.
Example
This example shows how to force Fast Ethernet front panel ports 1 through 5 to reauthenticate:
14.3.3.10set macauthentication macreauthenticate
Use this command to force an immediate reauthentication of a MAC address.
set macauthentication macreauthenticate mac_addr
Syntax Description
Command Type
Switch command.
Command Mode
Read-Write.
port-string (Optional) Forces reauthentication of specific MAC
authentication port(s). For a detailed description of possible
port-string values, refer to Section 4.1.2.
Matrix>set macauthentication portreauthentication fe.0.1-5
mac_addr Specifies the MAC address of the session to reauthenticate.