SNMP Command Set
Configuring SNMP Notification Parameters
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 5-51
Example
This example shows how to display the status of the new MAC address trap function on all Gigabit
Ethernet ports:
5.2.7.5 set newaddrtrap
Use this command to enable or disable SNMP trap messaging, globally or on one or more ports,
when new source MAC addresses are detected.
set newaddrtrap [port-string] {enable | disable}
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Matrix>show newaddrtrap ge.*.*
New Address Trap Globally disabled
Port Enable State
------- -----------
ge.0.1 disabled
ge.0.2 disabled
ge.0.3 disabled
ge.0.4 disabled
ge.0.5 disabled
ge.0.6 disabled
NOTE: Transmitting SNMP new address traps requires that you configure the device
with the SNMP management station information using the set trap command as
described in Section 5.2.7.2.
port-string (Optional) Enables or disables the MAC address trap
function on specific port(s). If new source MAC
addresses are detected via these ports, an SNMP trap
message will be sent to the management station.
enable | disable Globally enables or disables the MAC address trap
function on all device ports.