General Configuration Command Set
Setting Basic Device Properties
3-48 Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
Command Alternative (v3.00.xx and previous)
set system baud rate
Example
This example shows how to set the console port baud rate to 19200:
3.2.2.22 show ip address
Use this command to display the local host port IP address, system mask and default gateway.
show ip address
Syntax Description
None.
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display the system IP address, the system mask and the default
gateway:
Matrix>set console baud 19200
Matrix>show ip address
System IP - 10.1.10.1
System Mask - 255.255.128.0
Default Gateway - 0.0.0.0