Port Configuration Command Set
Configuring Static Port Trunking
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 4-51
4.3.11.1 show trunk
Use this command to display trunking information for the device. Output will vary depending on
the link aggregation mode of the device, as shown in the examples below.
show trunk [trunk_name]
Syntax Description
Command Defaults
If trunk_name is not specified, information for all trunks will be displayed.
Command Type
Switch command.
Command Mode
Read-Only.
Examples
This example shows how to display trunking information when the device is in 802.3ad mode:
trunk_name (Optional, portTrunking mode only) Displays trunking
information for a specific trunk.
Matrix>show trunk
Device is in 802.3AD mode.
Trunking algorithm is round robin.
LACP Rx/Tx is globally enabled.
System Identifier: 00:01:f4:c5:f7:f0
Agg OKey ports
-----------------------------------------------------------
lag.0.1 100 fe.0.1 fe.0.2 fe.0.3 fe.0.4
Slag.0.2 100 None
lag.0.3 100 None
lag.1.1 11 None
lag.1.2 12 None
lag.2.1 100 None