Logging and Network Management Command Set
Configuring Simple Network Time Protocol (SNTP)
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 11-65
11.2.4.7 set timezone
Use this command to set the SNTP time zone name and hours and minutes it is offset from
Coordinated Universal Time (UTC).
set timezone name [hours] [minutes]
Syntax Description
Command Defaults
If offset hours or minutes are not specified, none will be applied.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the time zone to EST with an offset of minus 5 hours:
11.2.4.8 clear timezone
Use this command to remove SNTP time zone adjustment values.
clear timezone
Syntax Description
None.
Command Defaults
None.
name Specifies the time zone name.
hours (Optional) Specifies the number of hours this timezone will
be offset from UTC. Valid values are minus 13 (-13) to 14.
minutes (Optional) Specifies the number of minutes this timezone
will be offset from UTC. Valid values are 0 to 59.
Matrix>set timezone ETS -5 0