EasyManua.ls Logo

Enterasys 1G58x-09 - Set Igmp Query-Interval; Show Igmp Response-Time

Enterasys 1G58x-09
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IGMP Configuration Command Set
Setting IGMP Query Interval and Response Time
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 10-5
10.2.2.2 set igmp query-interval
Use this command to set the IGMP query interval as defined in RFC 2236, Section 8.2.
set igmp query-interval intervaltime
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the IGMP query interval to 60 seconds:
10.2.2.3 show igmp response-time
Use this command to display the IGMP response time setting.
show igmp response-time
Syntax Description
None.
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Only.
intervaltime Specifies the frequency of host-query frame
transmissions. Valid values are from 30 to 600 seconds.
Matrix>set igmp query-interval 60