Logging and Network Management Command Set
Configuring System Logging
11-16 Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
11.2.1.12set logging application
Use this command to set the severity level of log messages for an application.
set logging application {mnemonic | all} level
Table 11-2 show logging application Output Details
Output What It Displays...
Application Mnemonic values for applications being logged. For details
on setting this value using the set logging application
command, refer to Section 11.2.1.12. For a list of valid values
and their corresponding applications, refer to Table 11-3.
Current Severity
Level
Severity level (from 1 to 8) at which the server is logging
messages for the listed application.
NOTE: Most system messages are logged at
severity level of 6 (Notice). By default, the logging
applications are set to 5 (Warning), which will
suppress level 6 (Notice) messages from the
console session. To view most of the logging of
configuration messages on the console session,
ACL hits etc, the set logging application
command should be used as described in
Section 11.2.1.12 to set the logging level for
applications to 6 or higher.