Logging and Network Management Command Set
Configuring System Logging
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 11-17
Syntax Description
mnemonic Specifies a case sensitive mnemonic value of an
application to be logged. Valid values and their
corresponding applications are listed in Table 11-3.
all Resets the severity level for all applications.
level Specifies the severity level at which the server will log
messages for applications. Valid values and
corresponding levels are:
1 - emergencies (system is unusable)
2 - alerts (immediate action required)
3 - critical conditions
4 - error conditions
5 - warning conditions
6 - notifications (significant conditions)
7 - informational messages
8 - debugging messages
NOTES: Mnemonic values are case sensitive and must be typed as they appear in
Table 11-3.
Most system messages are logged at severity level of 6 (Notice). By default, the logging
applications are set to 5 (Warning), which will suppress level 6 (Notice) messages from
the console session. To view most of the logging of configuration messages on the
console session, ACL hits etc, the set logging application command should be used to
set the logging level for applications to 6 or higher.
Session-oriented events, such as ACL hits and classification matches, will display
notification messages periodically with a counter, while other actions will trigger logging
for each event.