Process Overview: Routing Protocol Configuration
Configuring VRRP
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 13-81
13.1.5.5 advertise-interval
Use this command to set the interval in seconds between VRRP advertisements. These are sent by
the master router to other routers participating in the VRRP master selection process, informing
them of its configured values. Once the master is selected, then advertisements are sent every
advertising interval to let other VRRP routers in this VLAN/VRID know the router is still acting as
master of the VLAN/VRID.
advertise-interval vlan vlan_id vrid interval
Syntax Description
Command Syntax of the “no” Form
The “no” form of this command clears the VRRP advertise interval value:
no advertise-interval vlan vlan_id vrid interval
Command Type
Router command.
Command Mode
Router configuration: Matrix>Router(config-router)#
Command Defaults
None.
NOTE: All routers with the same VRID should be configured with the same
advertisement interval.
vlan vlan_id Specifies the number of the VLAN on which to configure
the VRRP advertisement interval. This VLAN must be
configured for IP routing as described in Section 3.3.2.
vrid Specifies a unique Virtual Router ID (VRID) associated
with the routing interface. Valid values are from 1 to 255.
interval Specifies a VRRP advertisement interval to associate with
the vrid. Valid values are from 1 to 255 seconds.