Spanning Tree Configuration Command Set
Reviewing and Setting Spanning Tree Bridge Parameters
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 6-25
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the maximum aging time to 25 seconds:
6.2.1.24 clear spantree maxage
Use this command to reset the bridge maximum aging time to the default value of 20 seconds.
clear spantree maxage
Syntax Description
None.
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
agingtime Specifies the maximum number of seconds that the system
retains the information received from other bridges through
STP. Valid values are 6 - 40.
Matrix>set spantree maxage 25