3-8
Related commands: schedule reboot at, schedule reboot delay.
Examples
# Display the information about scheduled reboot.
<Sysname> display schedule reboot
System will reboot at 16:00:00 2002/11/1 (in 2 hours and 5 minutes).
display transceiver alarm interface
Syntax
display transceiver alarm interface [ interface-type interface-number ]
View
Any view
Parameters
interface-type interface-number: Interface type and interface number.
Description
Use the display transceiver alarm interface command to display the current alarm information of a
single or all transceivers.
If no error occurs, None is displayed.
Table 3-7 shows the alarm information that may occur for the four types of transceivers.
Table 3-7 Description on the fields of display transceiver alarm interface
Field Remarks
GBIC/SFP
RX loss of signal RX signal is lost.
RX power high RX power is high.
RX power low RX power is low.
TX fault TX fault
TX bias high TX bias current is high.
TX bias low TX bias current is low.
TX power high TX power is high.
TX power low TX power is low.
Temp high Temperature is high.
Temp low Temperature is low.
Voltage high Voltage is high.
Voltage low Voltage is low.
Transceiver info I/O error Transceiver information read and write error
Transceiver info checksum error Transceiver information checksum error

Table of Contents

Other manuals for H3C S3600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3600 Series and is the answer not in the manual?

H3C S3600 Series Specifications

General IconGeneral
BrandH3C
ModelS3600 Series
CategorySwitch
LanguageEnglish

Related product manuals