1-24
test-enable
Syntax
test-enable
undo test-enable
View
HWPing test group view
Parameters
None
Description
Use the test-enable command to enable a HWPing test.
Use the undo test-enable command to disable a HWPing test.
Related commands: display hwping.
The result of the HWPing test cannot be displayed automatically, and you need to use the display
hwping command to display the test result.
Examples
# Perform a HWPing test on an ICMP test group with the administrator name and operation tag being
administrator and icmp respectively.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] hwping administrator icmp
[Sysname-hwping-administrator-icmp] test-type icmp
[Sysname-hwping-administrator-icmp] destination-ip 169.254.10.3
[Sysname-hwping-administrator-icmp] test-enable
test-failtimes
Syntax
test-failtimes times
undo test-failtimes
View
HWPing test group view
Parameters
times: Number of times of consecutive test failure, in the range of 1 to 15.

Table of Contents

Other manuals for H3C S3600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3600 Series and is the answer not in the manual?

H3C S3600 Series Specifications

General IconGeneral
BrandH3C
ModelS3600 Series
CategorySwitch
LanguageEnglish

Related product manuals