3-11
Table 3-8 Description on the fields of display transceiver alarm interface
Field Description
transceiver current alarm information Current alarm information of the transceiver
TX fault TX fault
display transceiver diagnosis interface
Syntax
display transceiver diagnosis interface [ interface-type interface-number ]
View
Any view
Parameters
interface-type interface-number: Interface type and interface number.
Description
Use the display transceiver diagnosis interface command to display the currently measured value of
digital diagnosis parameters of a single or all anti-spoofing transceivers customized by H3C.
Examples
# Display the currently measured value of digital diagnosis parameters of the anti-spoofing pluggable
optical transceiver customized by H3C on interface GigabitEthernet 1/1/2.
<Sysname> display transceiver diagnosis interface gigabitethernet 1/1/2
GigabitEthernet1/1/2 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19
Table 3-9 Description on the fields of display transceiver diagnosis interface
Field Description
transceiver diagnostic information
Digital diagnosis information of the transceiver
carried by an interface
Current diagnostic parameters Current diagnostic parameters
Temp.(°C)
Digital diagnosis parameter-temperature, in °C,
with the precision to 1°C.
Voltage(V)
Digital diagnosis parameter-voltage, in V, with
the precision to 0.01 V.
Bias(mA)
Digital diagnosis parameter-bias current, in mA,
with the precision to 0.01 mA.
RX power(dBM)
Digital diagnosis parameter-RX power, in dBM,
with the precision to 0.01 dBM.