1-9
display diagnostic-information
Syntax
display diagnostic-information
View
Any view
Parameters
None
Description
Use the display diagnostic-information command to display or save the running statistics of the
system function modules. If you choose to save the statistics, the system will save the statistics to a file
with the extension .diag in the Flash memory.
Examples
# Save the running statistics of the system function modules to the file default.diag.
<Sysname> display diagnostic-information
This operation may take a few minutes, continue?[Y/N]y
Diagnostic-information is saved to Flash or displayed(Y=save N=display)?[Y/N]y
Please input the file name(*.diag)[flash:/default.diag]:
The file is already existing, overwrite it? [Y/N]y
% Output information to file: flash:/default.diag.
Please wait......
After saving the information, you can use the more default.diag command in user view to view the
contents of the file (default.diag) with the Page Up and Page Down keys.
# Display the running statistics of the system function modules.
<Sysname> display diagnostic-information
This operation may take a few minutes, continue?[Y/N]y
Diagnostic-information is saved to Flash or displayed(Y=save N=display)?[Y/N]n
-------------------- display version --------------------
……
<Omitted>
terminal debugging
Syntax
terminal debugging
undo terminal debugging
View
User view

Table of Contents

Other manuals for H3C S3600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3600 Series and is the answer not in the manual?

H3C S3600 Series Specifications

General IconGeneral
BrandH3C
ModelS3600 Series
CategorySwitch
LanguageEnglish

Related product manuals