1-68
Use the undo timer realtime-accounting command to restore the default real-time accounting
interval.
By default, the real-time accounting interval is 12 minutes.
Note that:
z To control the interval at which users are charged in real time, you can set the real-time accounting
interval. After the setting, the switch periodically sends online users' accounting information to
TACACS accounting server at the set interval.
z The setting of the real-time accounting interval depends, to some degree, on the performance of
the switch and the TACACS server. The higher the performance of the switch and the TACACS
server is, the shorter the interval can be. It is recommended to set the interval as long as possible
when the number of users is relatively great (1000). The following table lists the recommended
intervals for different numbers of users.
Table 1-7 Numbers of users and recommended intervals
Number of users Real-time accounting interval
1 to 99 3
100 to 499 6
500 to 999 12
1000 15
Examples
# Set the real-time accounting interval in HWTACACS scheme hwt1 to 51 minutes.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] hwtacacs scheme hwt1
[Sysname-hwtacacs-hwt1] timer realtime-accounting 51
timer response-timeout
Syntax
timer response-timeout seconds
undo timer response-timeout
View
HWTACACS scheme view
Parameters
seconds: Response timeout time of TACACS servers, ranging from 1 to 300 seconds.
Description
Use the timer response-timeout command to set the response timeout time of TACACS servers.
Use the undo timer response-timeout command to restore the default response timeout time of
TACACS servers.