EasyManuals Logo

H3C S3600 Series Command Manual

H3C S3600 Series
1277 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #601 background imageLoading...
Page #601 background image
1-2
Offline detect period is 300s
Quiet period is 60 second(s).
Server response timeout value is 100s
Guest VLAN re-authenticate period is 30s
Max allowed user number is 1024
Current user number amounts to 1
Current domain: not configured, use default domain
Silent Mac User info:
MAC ADDR From Port Port Index
--- On unit 1, 1 silent mac address(es) found. ---
0016-e0be-e201 Ethernet1/0/2 1(vlan:1)
--- 1 silent mac address(es) found. ---
Ethernet1/0/1 is link-up
MAC address authentication is Enabled
max-auth-num is 256
Guest VLAN is 2
Authenticate success: 1, failed: 0
Current online user number is 1
MAC ADDR Authenticate state AuthIndex
000d-88f8-4e71 MAC_AUTHENTICATOR_SUCCESS 0
……(The following is omitted)
Table 1-1 Description on the fields of the display mac-authentication command
Field Description
Mac address authentication is Enabled MAC address authentication is enabled.
Authentication mode
Username type used in the MAC address
authentication:
z UsernameFixed: Uses the fixed username for
authentication.
z UsernameAsMacAddress: Uses the MAC address of
a user as the username for authentication.
The default is the MAC address
(UsernameAsMacAddress).
Fixed password
Meaning of this field varies by the username type for
MAC address authentication:
z If the username type is MAC address, this field
indicates whether to use a fixed password for
authentication. By default, this field is not configured,
which means using the MAC address of a user as the
password for authentication.
z If the username type is fixed username, this field
indicates whether a fixed password is configured. By
default, this field is not configured, which means the
password is null.
Fixed password
Password used in the fixed mode, which is not
configured by default.
Offline detect period
Offline detect timer, which sets the time interval to check
whether a user goes offline and defaults to 300
seconds.

Table of Contents

Other manuals for H3C S3600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3600 Series and is the answer not in the manual?

H3C S3600 Series Specifications

General IconGeneral
BrandH3C
ModelS3600 Series
CategorySwitch
LanguageEnglish

Related product manuals