Remote Control Commands
R&S
®
SMW200A
1022User Manual 1175.6632.02 ─ 16
[:SOURce]:BB:MEASurement:POWer:PEAK?
Queries the peak power of the baseband signal at the measurement point determined
with the command [:SOURce]:BB:MEASurement:POWer:OUTPut.
Return values:
<PeakPower> <Peak_SubMes#1>,<Peak_SubMes#2>,...
Returns the peak power of the measured signal or if a multi-
gated acquisition is used, a string of measured values with one
value per performed submeasurement
Range: -145 to 30
Example: See Example "Querying information on burst baseband signals
using the multi-gated acquisition" on page 1019
Usage: Query only
Manual operation: See "Level/PEP" on page 596
[:SOURce]:BB:MEASurement:POWer:RMS?
Queries the RMS power of the baseband signal at the measurement point determined
with the command [:SOURce]:BB:MEASurement:POWer:OUTPut.
Return values:
<RmsPower> <Power_SubMes#1>,<Level_SubMes#2>,...
Returns the power of the measured signal or if a multi-gated
acquisition is used, a string of measured values with one value
per performed submeasurement
Range: -145 to 30
Example: See Example "Querying information on burst baseband signals
using the multi-gated acquisition" on page 1019
Usage: Query only
Manual operation: See "Level/PEP" on page 596
[:SOURce]:BB:MEASurement:POWer:RSTate?
Queries the state (running/stopped) of the current measurement.
Return values:
<RunState> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Querying information on burst baseband signals
using the multi-gated acquisition" on page 1019
Usage: Query only
Manual operation: See "Running/Stopped" on page 597
SOURce Subsystem