Remote Control Commands
R&S
®
SMW200A
1058User Manual 1175.6632.02 ─ 16
Parameters:
<SRate> float
Range for FADER connectors: 100E6|200E6
Range: 400 to depends on connected receiving device
*RST: 1E8
Example: See [:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:SRATe:
SOURce on page 1057
Manual operation: See "Sample Rate Value" on page 181
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:CDEVice?
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:CDEVice?
Queries information on the connected device.
Return values:
<CDevice> string
Example:
:SOURce:IQ:OUTPut:DIGital:BBMM2:CDEVice?
Usage: Query only
Manual operation: See "Connected Device" on page 181
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:POWer:VIA <Via>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:POWer:VIA <Via>
Parameters:
<Via> PEP | LEVel
*RST: PEP
Manual operation: See "Signal Output" on page 183
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:POWer:PEP <Pep>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:POWer:PEP <Pep>
Enters the peak level of the output signal relative to full scale of 0.5 V (in terms of dB
full scale).
Parameters:
<Pep> float
Range: -60 to 0
Increment: 0.01
*RST: 0
Example:
:SOURce:IQ:OUTPut:DIGital:BBMM2:POWer:PEP -10
Manual operation: See "Signal Output" on page 183