Remote Control Commands
R&S
®
SMW200A
1144User Manual 1175.6632.02 ─ 16
:TEST:BB:GENerator:ARBitrary <Filename>
Selects the ARB waveform to be tested.
Parameters:
<Filename> string
Example: 
TEST:BB:GENerator:ARBitrary "3gpp.wv"
// Tests the loaded waveform, generating a 3GPP signal
Manual operation:  See "Select ARB File" on page 1166
:TEST:BB:GENerator:FREQuency 
<Frequency>
Sets the frequency of the test sine or constant I/Q test signal.
Parameters:
<Frequency> float
Range:  -80E6  to  80E6
Increment:  1E-3
*RST:  1E6
Example: 
TEST:BB:GENerator:FREQuency 50 MHz
Manual operation:  See "Frequency" on page 1166
:TEST:BB:GENerator:GAIN <Gain>
Sets the gain for a sine or constant I/Q test signal.
Parameters:
<Gain> float
Range:  -1  to  1
Increment:  1E-6
*RST:  1
Example: 
TEST:BB:GENerator:GAIN 0.5
// amplifies the test signal by a factor of 0.5
Manual operation:  See "Gain" on page 1165
:TEST:BB:GENerator:SOURce <IqSource>
Selects the test signal source.
TEST Subsystem