Remote Control Commands
R&S
®
SMW200A
1144User Manual 1175.6632.02 ─ 16
:TEST:BB:GENerator:ARBitrary <Filename>
Selects the ARB waveform to be tested.
Parameters:
<Filename> string
Example:
TEST:BB:GENerator:ARBitrary "3gpp.wv"
// Tests the loaded waveform, generating a 3GPP signal
Manual operation: See "Select ARB File" on page 1166
:TEST:BB:GENerator:FREQuency
<Frequency>
Sets the frequency of the test sine or constant I/Q test signal.
Parameters:
<Frequency> float
Range: -80E6 to 80E6
Increment: 1E-3
*RST: 1E6
Example:
TEST:BB:GENerator:FREQuency 50 MHz
Manual operation: See "Frequency" on page 1166
:TEST:BB:GENerator:GAIN <Gain>
Sets the gain for a sine or constant I/Q test signal.
Parameters:
<Gain> float
Range: -1 to 1
Increment: 1E-6
*RST: 1
Example:
TEST:BB:GENerator:GAIN 0.5
// amplifies the test signal by a factor of 0.5
Manual operation: See "Gain" on page 1165
:TEST:BB:GENerator:SOURce <IqSource>
Selects the test signal source.
TEST Subsystem