EasyManua.ls Logo

Rohde & Schwarz SMW200A - Page 284

Rohde & Schwarz SMW200A
1312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Internal Baseband Source
R&S
®
SMW200A
269User Manual 1175.6632.02 ─ 16
2. If higher order modulation is required, select for example "Modulation > Modulation
Type > PSK > QPSK".
Settings:
Data Source................................................................................................................ 269
Select Data List...........................................................................................................270
Select Control List.......................................................................................................270
Receiver State.............................................................................................................271
Settings for Data Source = External............................................................................271
Symbol Clock Slope/Clock Slope..................................................................271
Bit Clock Slope..............................................................................................272
Bit Order........................................................................................................272
Clock to Data Time Deviation....................................................................... 272
Throughput Delay......................................................................................... 272
Graphical illustration of the timing ratios between the data and clock signals
......................................................................................................................273
Local Connector Settings............................................................................................273
Data Source
Selects the data source (see Chapter 4.5.1.1, "Data, Clock and Control Signals and
Sources in the Baseband", on page 227).
The following data sources are available:
"All 0, All 1"
A sequence containing 0 data or 1 data is internally generated
"PRBS, PRBS Type"
Selects internally generated PRBS data in accordance with the IUT-
T. Use the parameter "PRBS Type" to define the length.
Remote command:
[:SOURce<hw>]:BB:DM:PRBS[:LENGth] on page 895
"Pattern"
Use the "Pattern" box to define a bit pattern with a maximum length of
64 bits.
Generating Custom Digital Modulated Signals

Table of Contents

Related product manuals