Configuring the Internal Baseband Source
R&S
®
SMW200A
270User Manual 1175.6632.02 ─ 16
"Data List"
Binary data from data lists are used, see Select Data List.
Remote command:
[:SOURce<hw>]:BB:DM:DLISt:CATalog? on page 913
[:SOURce<hw>]:BB:DM:DLISt:SELect on page 913
"External"
(requires R&S SMW-B10)
An externally supplied serial data is used, see "External Modulation
Data" on page 229.
Data and clock signals are expected at the corresponding connec-
tors.
Remote command:
[:SOURce<hw>]:BB:DM:SOURce on page 894
Select Data List
Accesses the standard "Select List" dialog to select an existing data list or to create a
new one.
Data lists can be generated externally or internally in the data editor.
●
Select the "Select Data List > navigate to the list file *.dm_iqd > Select" to select an
existing data list.
●
Use the standard "File Manager" function to transfer external data lists to the
instrument.
●
Use the "New" and "Edit" functions to create internally new data list or to edit an
existing one, see Chapter 4.6.3.7, "Data List Editor", on page 280.
See also Chapter 4.6.4.2, "How to Create and Assign a Data List", on page 288
Remote command:
[:SOURce<hw>]:BB:DM:DLISt:CATalog? on page 913
[:SOURce<hw>]:BB:DM:DLISt:SELect on page 913
[:SOURce<hw>]:BB:DM:DLISt:COPY on page 916
[:SOURce<hw>]:BB:DM:DLISt:DELete on page 914
Select Control List
Accesses the standard "Select List" dialog to select an existing control list or to create
a new one.
Control lists can be generated externally or internally in the "Control and Marker Lists"
editor.
●
Select the "Select Control List > navigate to the list file *.dm_iqc > Select" to select
an existing control list.
●
Use the standard "File Manager" function to transfer external lists to the instrument.
●
Use the "New" and "Edit" functions to create internally new list or to edit an existing
one, see Chapter 4.6.3.8, "Control and Marker Lists Editor", on page 282.
Irrespectively on the way they are created, control lists are not automatically used (see
"How to assign and activate control signals from a control list" on page 287).
Remote command:
[:SOURce<hw>]:BB:DM:CLISt:CATalog? on page 913
[:SOURce<hw>]:BB:DM:CLISt:SELect on page 913
Generating Custom Digital Modulated Signals