Remote Control Commands
R&S
®
SMW200A
798User Manual 1175.6632.02 ─ 16
:DISPlay:PSAVe:HOLDoff <HoldoffTimeMin>
Sets the wait time for the screen saver mode of the display.
Parameters:
<HoldoffTimeMin> integer
Range: 1 to 60
*RST: n.a. (factory preset: 10)
Default unit: minute
Example: see Example "Activating screen saver mode and display update"
on page 797
Manual operation: See "Wait Time" on page 658
:DISPlay:PSAVe[:STATe]
<State>
Activates the screen saver mode of the display.
We recommend that you use this mode to protect the display, if you operate the instru-
ment in remote control.
To define the wait time, use the command :DISPlay:PSAVe:HOLDoff.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 0)
Example: See Example "Activating screen saver mode and display
update" on page 797
Manual operation: See "Screen Saver" on page 658
:DISPlay:UPDate <Update>
Activates the refresh mode of the display.
Parameters:
<Update> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 1)
Example: See Example "Activating screen saver mode and display
update" on page 797
Manual operation: See "Display Update is" on page 660
:DISPlay:ANNotation:AMPLitude <State>
Indicates asterisks instead of the level values in the status bar.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: n.a. (factory preset: 1)