Remote Control Commands
R&S
®
SMW200A
883User Manual 1175.6632.02 ─ 16
[:SOURce<hw>]:PULM:DELay <Delay>
Sets the pulse delay.
Parameters:
<Delay> float
*RST: 1ms
Example: See Example "Perform pulse modulation" on page 881.
Manual operation: See "Pulse Delay" on page 516
[:SOURce<hw>]:PULM:DOUBle:DELay
<Delay>
Sets the delay from the start of the first pulse to the start of the second pulse.
Parameters:
<Delay> float
*RST: 1E-6
Example: See Example "Perform pulse modulation" on page 881.
Manual operation: See "Double Pulse Delay" on page 516
[:SOURce<hw>]:PULM:DOUBle:WIDTh <Width>
Sets the width of the second pulse.
Parameters:
<Width> float
Increment: 5E-9
Example: See Example "Perform pulse modulation" on page 881.
Manual operation: See "Double Pulse Width" on page 516
[:SOURce<hw>]:PULM:POLarity <Polarity>
Sets the polarity of the externally applied modulation signal.
Parameters:
<Polarity> NORMal | INVerted
NORMal
Suppresses the RF signal during the pulse pause.
INVerted
Suppresses the RF signal during the pulse.
*RST: NORMal
Example: See Example "Perform pulse modulation" on page 881.
Manual operation: See "Polarity Pulse Input" on page 514
SOURce Subsystem