EasyManua.ls Logo

Rohde & Schwarz SMW200A - Page 903

Rohde & Schwarz SMW200A
1312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMW200A
888User Manual 1175.6632.02 ─ 16
Parameters:
<POffset> float
Range: 0 to 359.9
Increment: 0.01
*RST: 0
Default unit: DEG
Example:
BB:POFF 0.5DEG
Sets a relative phase offset of 0.5 DEG for the baseband signal
Manual operation: See "Phase Offset" on page 386
[:SOURce<hw>]:BB:PGAin <PGain>
[:SOURce<hw>]:BBIN:PGAin <PGain>
Sets the relative gain for the internal or external baseband signal compared with the
signals of the other baseband sources.
Parameters:
<PGain> float
Range: -50 to 50
Increment: 1E-3
*RST: 0
Default unit: dB
Example:
BBIN:PGA 3dB
Sets the relative gain of 3 dB for the external baseband signal.
Manual operation: See "Gain" on page 387
[:SOURce<hw>]:BB:ROUTe <Route>
[:SOURce<hw>]:BBIN:ROUTe <Route>
Selects the signal route for the internal/external baseband signal. The internal and
external signals are summed if necessary.
Parameters:
<Route> A | B | AB
Example:
BBIN:ROUT A
The external baseband signal is introduced into path A.
Options: R&S SMW-B10
Manual operation: See "Signal Routing" on page 170
[:SOURce<hw>]:BB:CODer:MODE <Mode>
Defines the source of the baseband generator.
SOURce Subsystem

Table of Contents

Related product manuals