4 Playback
4.2 Playback
4-13
155507-1CD
RE-CSO-A037
DX100
4.2.2.4 Machine Lock Operation
A job is played back without moving the manipulator to check the status of
input and output.
1. Select “MACHINE LOCK” under the SPECIAL PLAY window.
The setting alternates between “VALID” and “INVALID”.
2. Select “COMPLETE”.
The window returns to the PLAYBACK window.
4.2.2.5 Check Mode Operation
The machine runs without issuing work instructions, such as the ARCON
instruction. It is used primarily to check the path of the program.
1. Select “CHECK-RUN” under the SPECIAL PLAY window.
The setting alternates between “VALID” and “INVALID”.
2. Select “COMPLETE”.
The window returns to the PLAYBACK window.
4.2.2.6 Weaving Prohibit Setting during Check Mode Operation
The weaving operation is not executed in the weaving section of the job.
1. Select “WEAV PROHIBIT IN CHK-RUN” under the SPECIAL PLAY
window.
The setting alternates between “VALID” and “INVALID”.
2. Select “COMPLETE”.
The window returns to the PLAYBACK window.
NOTE
• The setting of “MACHINE LOCK” is maintained even after
the mode is switched: If the machine lock is set to “VALID”
in the teach mode, it is still “VALID” after switching to the
play mode.
The same applies when the mode is switched from the
play mode to the teach mode.
• Note that the machine lock becomes “INVALID” if the
following operation is performed.
• Execution of “CANCEL ALL SELECT” in the SPECIAL
PLAY window.
• Turning off the main power.
202 of 554

Table of Contents

Other manuals for YASKAWA DX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA DX100 and is the answer not in the manual?

YASKAWA DX100 Specifications

General IconGeneral
Programming LanguageInform III
Compatible RobotsMotoman robots
Operating Temperature0-45°C
Humidity20-80% RH (non-condensing)
Protection ClassIP20
InterfaceEthernet
Safety StandardsANSI/RIA R15.06-1999
PendantAvailable
I/O Capacity1024 inputs / 1024 outputs
Storage Temperature-10-60°C

Related product manuals