Remote Control Commands
R&S
®
SMW200A
815User Manual 1175.6632.02 ─ 16
:SENSe<ch>[:POWer]:FILTer:TYPE................................................................................ 821
:SENSe<ch>[:POWer]:FREQuency..................................................................................822
:SENSe<ch>[:POWer]:LOGGing:STATe...........................................................................822
:SENSe<ch>[:POWer]:OFFSet........................................................................................823
:SENSe<ch>[:POWer]:OFFSet:STATe.............................................................................823
:SENSe<ch>[:POWer]:SNUMber?................................................................................... 823
:SENSe<ch>[:POWer]:SOURce.......................................................................................824
:SENSe<ch>[:POWer]:STATus[:DEVice]?........................................................................ 824
:SENSe<ch>[:POWer]:SVERsion?...................................................................................824
:SENSe<ch>[:POWer]:TYPE?.........................................................................................824
:SENSe<ch>[:POWer]:ZERO.......................................................................................... 825
:SLISt[:LIST]?
Returns a list of all detected sensors in a comma-separated string.
Return values:
<SensorList> String of comma-separated entries
Each entry contains information on the sensor type, serial num-
ber and interface.
The order of the entries does not correspond to the order the
sensors are displayed in the "NRP Sensor Mapping" dialog.
Example: See Example "Detecting and assigning a power sensor"
on page 813.
Usage: Query only
Manual operation: See " Sensor Mapping List " on page 542
:SLISt:SCAN[:STATe] <State>
Starts the search for R&S NRP power sensors, connected in the LAN or via the
USBTMC protocol.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Detecting and assigning a power sensor"
on page 813.
Manual operation: See " Scan " on page 543
:SLISt:ELEMent<ch>:MAPPing <Mapping>
Assigns an entry from the :SLISt[:LIST]? to one of the four sensor channels.