Remote Control Commands
R&S
®
SMW200A
851User Manual 1175.6632.02 ─ 16
Example: see Example "Connecting and configuring external instrument
(advanced configuration)" on page 826
Usage: Setting only
:SCONfiguration:EXTernal:CODer<ch>:REMote:DETect?
:SCONfiguration:EXTernal:FADer<ch>:REMote:DETect?
:SCONfiguration:EXTernal:BBMM<ch>:REMote:DETect?
Searches for external instruments connected to the particular digital interfaces.
Return values:
<DetectedInstr> string
If the detection fails, the query returns "None".
Example: see Example "Connecting and configuring external instrument
(advanced configuration)" on page 826
Usage: Query only
Manual operation: See "Detect/Scan" on page 156
:SCONfiguration:EXTernal:CODer<ch>:REMote:ISELect <InstrName>[, <RfPath>]
:SCONfiguration:EXTernal:FADer<ch>:REMote:ISELect <InstrName>[, <RfPath>]
:SCONfiguration:EXTernal:BBMM<ch>:REMote:ISELect <InstrName>[, <RfPath>]
:SCONfiguration:EXTernal:IQOutput<ch>:REMote:ISELect <InstrName>[,
<RfPath>]
Select an external instrument for the selected connector.
Parameters:
<InstrName> String
Instrument alias name, as retrieved with the command :
SCONfiguration:EXTernal:REMote:LIST? or defined with
the command :SCONfiguration:EXTernal:REMote:ADD.
<RfPath> String
Determines the used RF output of the external instrument.
Example: See Example "Connecting and configuring external instrument
(advanced configuration)" on page 826
Manual operation: See "Select Instrument" on page 157
:SCONfiguration:EXTernal:CODer<ch>:REMote:CONNect
:SCONfiguration:EXTernal:FADer<ch>:REMote:CONNect
:SCONfiguration:EXTernal:BBMM<ch>:REMote:CONNect
:SCONfiguration:EXTernal:IQOutput<ch>:REMote:CONNect
Triggers the connection establishment.
Example:
see Example "Connecting and configuring external instrument
(advanced configuration)" on page 826
SCONfiguration Subsystem